4,504 research outputs found

    Newcomers Meet the Intracluster Medium in the Coma Cluster

    Full text link
    A main topic at this meeting is how galaxies are affected when they enter for the first time the cluster environment from the outskirts. Most of the times we are forced to infer the environmental effects indirectly, relying on systematic variations of galaxy properties with environment, but there aren't many examples of direct observations able to unveil ongoing transformations taking place, and the corresponding mechanism producing it. We present a case in which it is possible to identify the cluster environment, and in particular the intracluster medium and the recent infall history of galaxies onto the cluster, as the cause for a recent, abrupt change in the evolutionary history of galaxies.Comment: 5 pages, 1 postscript figure -- to appear in "Outskirts of Galaxy Clusters: intense life in the suburbs", IAU Colloquium N. 195, 2004, ed. A Diaferi

    Evaluating the peak-to-valley dose ratio of synchrotron microbeams using PRESAGE fluorescence

    Get PDF
    Synchrotron-generated microbeam radiotherapy holds great promise for future treatment, but the high dose gradients present conventional dosimetry with a challenge. Measuring the important peak-to-valley dose ratio (PVDR) of a microbeam-collimated synchrotron source requires both a dosimeter and an analysis method capable of exceptional spatial resolution. The PVDR is of great interest since it is the limiting factor for potential application of the microbeam radiation therapy technique clinically for its tissue-sparing properties (i.e. the valley dose should be below the tolerance of normal tissue). In this work a new method of measuring the dose response of PRESAGE dosimeters is introduced using the fluorescence from a 638 nm laser on a confocal laser-scanning microscope. This fluorescent microscopy method produces dosimetry data at a pixel size as low as 78 nm, giving a much better spatial resolution than optical computed tomography, which is normally used for scanning PRESAGE dosimeters. Using this technique the PVDR of the BL28B2 microbeam at the SPring-8 synchrotron in Japan is estimated to be approximately 52:1 at a depth of 2.5 mm. The PVDR was also estimated with EBT2 GAFchromic films as 30.5:1 at the surface in order to compare the PRESAGE fluorescent results with a more established dosimetry system. This estimation is in good agreement with previously measured ratios using other dosimeters and Monte Carlo simulations. This means that it is possible to use PRESAGE dosimeters with confocal microscopy for the determination of PVDR

    \Omega-deformation of B-twisted gauge theories and the 3d-3d correspondence

    Full text link
    We study \Omega-deformation of B-twisted gauge theories in two dimensions. As an application, we construct an \Omega-deformed, topologically twisted five-dimensional maximally supersymmetric Yang-Mills theory on the product of a Riemann surface Σ\Sigma and a three-manifold MM, and show that when Σ\Sigma is a disk, this theory is equivalent to analytically continued Chern-Simons theory on MM. Based on these results, we establish a correspondence between three-dimensional N=2\mathcal{N} = 2 superconformal theories and analytically continued Chern-Simons theory. Furthermore, we argue that there is a mirror symmetry between {\Omega}-deformed two-dimensional theories.Comment: 26 pages. v2: the discussion on the boundary condition for vector multiplet improved, and other minor changes mad

    Measurements of Thermophysical Property of Thin Films by Light Pulse Heating Thermoreflectance Methods

    Get PDF
    Thermoreflectance methods by picosecond pulse heating and by nanosecond pulse heating have been developed under the same geometrical configuration as the laser flash method by the National Metrology Institute of JAPAN, AIST. Using these light pulse heating methods, thermal diffusivity of each layer of multilayered thin films and boundary thermal resistance between the layers can be determined from the observed transient temperature curves based on the response function method. The measurement results of various thin films as transparent conductive films used for flat panel displays, hard coating films and multilayered films of the next generation phase-change optical disk will be presented.Comment: Submitted on behalf of TIMA Editions (http://irevues.inist.fr/tima-editions

    Meissner effect in honeycomb arrays of multi-walled carbon nanotubes

    Full text link
    We report Meissner effect for type-II superconductors with a maximum Tc of 19 K, which is the highest value among those in new-carbon related superconductors, found in the honeycomb arrays of multi-walled CNTs (MWNTs). Drastic reduction of ferromagnetic catalyst and efficient growth of MWNTs by deoxidization of catalyst make the finding possible. The weak magnetic anisotropy, superconductive coherence length (- 7 nm), and disappearance of the Meissner effect after dissolving array structure indicate that the graphite structure of an MWNT and those intertube coupling in the honeycomb array are dominant factors for the mechanism.Comment: 6 page
    corecore